TMP for gas turbines F8-H10

TMP for gas turbines F8-H10 Technical information (PDF 57,4 kB)

The TMP compact filter elements consist of 4 V elements on both sides sealed with polyurethane in a plastic frame. The two-sided sealing of the filter pleat makes the filter resistant to dripping condensate and ensures a long useful life under extreme conditions.

Field of application: Gas turbines, plate power units, compressors, and air conditioning units of power plants.
Waste disposal: Incineration in authorised incineration plants.

Technická data dle EN 779 a EN 1822KS TMPKS TMPC
Filtration classF8F9E10
MaterialGlass submicron filter paper
Possibility of regenerationNo
Supply of material 592 x 592, 287 x 592, 490 x 592, 402 x 592
Mean efficiency degree (gravimetric) (%)99∼ 100∼ 100
Mean efficiency degree (atmospheric) (%)90-95>9598
Nominal air flow rate (m3/h) VR/VN3400/42503400/42503000/3400
Initial pressure loss at nominal load (Pa) VR/VN90/13098/140140
Recommended final pressure loss (Pa)450450450
Maximum thermal resistance (max °C)≤70≤70

Pressure loss diagram
Pressure loss diagram